Violation Detail
Standard Cited: 5A0001 OSH Act General Duty Paragraph
Inspection Nr: 304986292
Citation: 01001
Citation Type: Serious
Abatement Status: I
Initial Penalty: $5,600.00
Current Penalty: $3,640.00
Issuance Date: 02/26/2002
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 03/01/2002
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order:
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/20/2002 | $3,640.00 | 03/01/2002 | Serious | |
Penalty | Z: Issued | 02/26/2002 | $5,600.00 | 03/01/2002 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: UNAPEQUIP
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: a. At the construction site of the Hernando Pain Clinic, located at 5193 Mariner Blvd in Spring Hill, Florida. The 62 foot metal plate connected wood roof trusses were installed without bracing as required by HIB-91 Summary Sheet Commentary and Recommendations for Handling, Installing and Bracing Metal Plate Connected Wood Trusses. The trusses were installed by using 1X3 wooden spacers with inadequate lateral, and ground bracing. A registered professional engineer was not consulted with regards to the temporary bracing arrangement for the 62 foot metal plate connected wood trusses. One feasible and acceptable abatement method to correct these hazards is to install roof trusses in accordance the Truss Plate Institutes recommendations which are contained in "HIB-91, Recommendations For Handling, Installing and Bracing Metal Plate Connected Wood Trusses". The truss manufacturer provides a copy of the "HIB-91 Summary Sheet" with the delivery of the truss information and their Design Criteria refers to the HIB-91 for proper handling, installing and bracing. The Standard Building Code also refers to the HIB-91 for handling, installing and bracing of metal plate connected wood trusses. Violation observed on 18 January 02.