Violation Detail
Standard Cited: 95012901
Inspection Nr: 304259559
Citation: 01001
Citation Type: Serious
Abatement Status: I
Initial Penalty: $500.00
Current Penalty: $350.00
Issuance Date: 07/09/2001
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/12/2001
Gravity:
Report ID: 0453710
Contest Date:
Final Order:
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/02/2001 | $350.00 | 07/12/2001 | Serious | |
| Penalty | Z: Issued | 07/09/2001 | $500.00 | 07/12/2001 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard: UNAPEQUIP
North Carolina General Statute 95-129(1) of the Occupational Safety and Health Act of North Carolina: The employer did not furnish each of his employees conditions of employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a)facility - where employees operated a Genie Boom that had an inoperable warning device (model Z-30/20HD, s/n 3086-1286) during overhead maintenance and repair activities throughout the facility. Abatement Note: One feasible and acceptable abatement method, among others, is to repair the warning device on the Genie boom lift. (Reference: Genie Operators Manual)rs