Standard Cited: 5A0001 OSH Act General Duty Paragraph

Inspection Nr: 302580618

Citation: 01001

Citation Type: Serious

Abatement Status: X

Initial Penalty: $2,125.00

Current Penalty: $100.00

Issuance Date: 11/18/1999

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 01/06/2000

Gravity: 03

Report ID: 1032500

Contest Date:

Final Order:

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 12/09/1999 $100.00 01/06/2000 Serious  
Penalty Z: Issued 11/18/1999 $2,125.00 01/06/2000 Serious  

Text For Citation: 01 Item/Group: 001 Hazard: DUST&FUMES

Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of explosion from the interior located dust collection system: (a)Building 1, Panel ripsaw area: The Macron 10 and 15 bag dust collection systems, including the cyclones, filter bags, and dust collector bins were located in the same interior room as two panel ripsaws. This exposed the operators to the hazard of fire and explosions. The dust control system was not equipped with an explosion suppression system such as venting, or a spark detection/spark suppression system. The air was recycled back into the work area through the filter bags. Among other methods, feasible and acceptable abatement method to correct this hazard are to modify the dust collection system to comply with NFPA 664, Chapter 8, which may include, but is not limited to: (1) Moving the dust collection system outside of buildings; (2) Vent the system outside through straight ducts no longer than 10 feet and install explosion deflagration vents; (3) Install an explosion suppression system meeting the requirements of NFPA 69, Standard on Explosion Prevention Systems. Note: Abatement certification required for this item.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close