Violation Detail
Standard Cited: 6A0001 General Duty Clause
Inspection Nr: 300144979
Citation: 01001
Citation Type: Serious
Abatement Status: X
Initial Penalty:
Current Penalty:
Issuance Date: 08/25/2000
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 09/14/2000
Gravity: 10
Report ID: 0257260
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Text For Citation: 01 Item/Group: 001 Hazard: FALLING
Section 6(a) of the Puerto Rico Occupational Safety and Health Act: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or physical harm to employees in that employees were exposed to: Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico: El patrono no proveyo empleo y un sitio de empleo libre de riesgos reconocidos que esten causando o que puedan causar muerte o dano fisico a los empleados, por cuanto empleados estaban expuestos a: In the San Juan Termoelectric Central of the Electrical Energy Authority in Puerto Nuevo - the exterior door of the elevator Tornborgs, with capacity of 4,800 pounds and with serial number 210- 137-U-7 & 8, of the boiler # 8, where the employer removed the rubber and the bushings that worked like a damping, created an aperture aproximate of 3". Created that one boiler tube of 2 1/2" of wide X 12" long and 1/4" thickness fell down through the aperture to 95 feet of height, fell down in a roof, rebound to the first floor, and falling them in the back cranium part of the employee. Hazard: Strokes Among other methods, one feasible and acceptable abatement method to correct this hazard is the inspection for all the elevators in the establisment to be in accordance with the ANSI/ASME A 10.4- 1990 for Car Doors, Gates and Electrical Contacts, part 18.2.4.2 " Vertically sliding counterweighted doors or gates shall be considered to be in the closed position when the clear open space between the leading edge of the door or gate and the sill of the car platform does not exced 2 inches ( 5.8cm). En la Central Termoelectrica de San Juan de la Autoridad de Energia Electrica de Puerto Nuevo - la puerta exterior del ascensor "Tornborgs, con capacidad de 4,800 libras y con numero de serie 210- 137-U-7 & 8, de la caldera # 8, donde el patrono removio la goma y los cojines ("bushings") que trabajaban como amortiguadores, creando una apertura de 3" aproximadamente. Creando que un tubo de caldera de 2 1/2" de ancho X 12" de largo y 1/4" de espesor cayera abajo por la apertura a 95 pies de altura, cayendo a un techo, rebotando entonces en el primer piso, y cayendo entonces en la parte trasera craneal del empleado. Riesgo: Golpes Entre otros metodos, un metodo aceptable y posible para corregir este riesgo es la inspeccion de todos los ascensores en el establecimiento para estar en concordancia con el ANSI/ASME A 10.4 - 1990 para, Puertas de Carro, Entradas y Contactos Electricos, parte 18.2.4."Puertas que abren y cierran verticalmente y por contrapeso seran consideradas cerradas cuando el espacio abierto entre el borde de la puerta y la superficie del piso del carro no exceda dos pulgadas (5.8cm).
Translate