Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 280226.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,500.00
Current Penalty: $3,850.00
Issuance Date: 07/11/2012
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/18/2012
Gravity: 5
Report ID: 0213100
Contest Date:
Final Order: 08/01/2012
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/01/2012 | $3,850.00 | 07/18/2012 | Serious | |
Penalty | Z: Issued | 07/11/2012 | $5,500.00 | 07/18/2012 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section: a) Thermoforming area- On and before 5/24/12- Employees perfroming maintenance operations on the Rennco autopackers were not provided energy control procedures that included steps for control of pneumatic and thermal energy.