Violation Detail
Standard Cited: 19100023 C02 Ladders.
Inspection Nr: 191151.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,200.00
Current Penalty: $4,200.00
Issuance Date: 07/25/2012
Nr Instances:
Nr Exposed: 1
Abatement Date: 08/15/2012
Gravity: 5
Report ID: 0521400
Contest Date: 08/10/2012
Final Order: 08/03/2015
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | 2: Appeals Court | 08/03/2015 | $4,200.00 | 08/15/2012 | Serious | |
| Penalty | C: Contested | 08/13/2012 | $4,200.00 | 08/15/2012 | Serious | |
| Penalty | Z: Issued | 07/25/2012 | $4,200.00 | 08/15/2012 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board. a) On or about February 6, 2012, Dukane Precast Incorporated did not maintain a standard railing adjacent to batch plant sand bins that are permit required confined spaces. The batch plant bin number 2 wall adjacent to the access platform extended 27 inches above the platform without additional railing. Abatement certification is required for this item in accordance with the rerquirements of 29 CFR 1903.19(c).
Translate