Violation Detail
Standard Cited: 19100147 F01 V The control of hazardous energy (lockout/tagout).
Inspection Nr: 1841432.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $13,240.00
Current Penalty: $8,440.00
Issuance Date: 09/30/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 11/19/2025
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/19/2025 | $8,440.00 | Serious | ||
| Penalty | Z: Issued | 09/30/2025 | $13,240.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(f)(1)(v): Deenergize all systems and reapply energy control measures in accordance with paragraph (d) of this section to continue the servicing and/or maintenance. On or about February 18, 2025, at the previously addressed job site, employees were performing servicing and maintenance of a machine without deenergizing after a function test to adjust a conveyor belt.
Translate