Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1819719.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,550.00
Current Penalty: $0.00
Issuance Date: 07/25/2025
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 08/29/2025
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 08/25/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/25/2025 | $0.00 | 08/29/2025 | Serious | |
Penalty | Z: Issued | 07/25/2025 | $16,550.00 | 08/29/2025 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section. a.) On or about April 10, 2025, the employer did not ensure an energy control procedure for the Keystone Actuator Model MRP-088U-K-D000 were developed, documented, and utilized by each authorized employee performing maintenance and testing on the equipment. As a result, an employee suffered an abdominal contusion and liver laceration when the piston shot out of the actuator and struck the employee.