Violation Detail
Standard Cited: 19261053 B13 Ladders.
Inspection Nr: 1817163.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,958.00
Current Penalty: $2,840.00
Issuance Date: 07/28/2025
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 10
Report ID: 0524200
Contest Date:
Final Order: 08/07/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/07/2025 | $2,840.00 | Serious | ||
| Penalty | Z: Issued | 07/28/2025 | $5,958.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.1053(b)(13): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On April 10, 2025, at the above addressed jobsite, the portable ladder used by employees to access and egress the roof of the house, measuring approximately 24 feet from ground to eve, did not have the side rails extend at least three (3) feet above the upper landing. No abatement certification or documentation is required for this item.