Violation Detail
Standard Cited: 19260651 C02 Specific Excavation Requirements.
Inspection Nr: 1802699.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $6,029.00
Current Penalty: $6,000.00
Issuance Date: 06/23/2025
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 07/23/2025
Gravity: 1
Report ID: 0627500
Contest Date:
Final Order: 07/08/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/08/2025 | $6,000.00 | 07/23/2025 | Other | |
Penalty | Z: Issued | 06/23/2025 | $6,029.00 | 07/03/2025 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees. On or about February 01, 2025, inside a trench that ran south-north at location; employees were working inside of the excavation with a depth greater than 4 feet without any safe means of access or exit.