Violation Detail
Standard Cited: 19100147 F01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1800955.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,550.00
Current Penalty: $16,550.00
Issuance Date: 04/18/2025
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 05/23/2025
Gravity: 10
Report ID: 0522000
Contest Date:
Final Order: 04/30/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/30/2025 | $16,550.00 | 05/23/2025 | Serious | |
Penalty | Z: Issued | 04/18/2025 | $16,550.00 | 05/23/2025 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.147(f)(1): Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed: a) On or about January 22, 2025, when performing testing of the rollers on the FBTI Furnace located in the Coating Department, the current lockout procedures will be updated to require the mantenance to place a barrier within 3 feet from te rollers and to stand behind a temporary barrier guard with signage when testing the rollers.