Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1792154.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $9,457.00
Current Penalty: $0.00
Issuance Date: 03/21/2025
Nr Instances: 1
Nr Exposed: 50
Abatement Date: 04/09/2025
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 04/14/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/14/2025 | $0.00 | 04/09/2025 | Serious | |
Penalty | Z: Issued | 03/21/2025 | $9,457.00 | 04/09/2025 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure the procedure and the requirement of this standard were followed: On or about December 5, 2024, and times prior to, the employer St. Francis Medical Clinic Poplar Bluff located at 221 Physician Park in Poplar Bluff, Missouri, had not conducted periodic inspections of their lockout/tagout hazardous energy control procedures at least annually to ensure procedures and the requirements of this standard were followed.