Violation Detail
Standard Cited: 19260452 W02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1791379.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,525.00
Current Penalty: $3,167.50
Issuance Date: 01/10/2025
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 1
Report ID: 1032500
Contest Date:
Final Order: 03/13/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/13/2025 | $3,167.50 | Serious | ||
| Penalty | Z: Issued | 01/10/2025 | $4,525.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: a) On November 4, 2024 and times prior the controlling employer, Beniton Construction did not ensure the drywall sub-contractor protected their employees from a fall hazard when multiple mobile scaffolds were used with the wheel caster locking mechanisms not engaged or missing completely. Note) Corrected during inspection.