Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1769454.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.00
Issuance Date: 09/27/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 12/31/2024
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/24/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/24/2024 | $12,098.00 | 12/31/2024 | Serious | |
Penalty | Z: Issued | 09/27/2024 | $16,131.00 | 11/01/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.147(c)(7)(i)(B) Each affected employee shall be instructed in the purpose and use of the energy control procedure. On or about August 8, 2024, the employer failed to ensure that the Minster Mechanical Power Press (Model 3, Herion 2493020, Serial #35/38) operators were trained as affected employees. The operators were not authorized employees and were incorrectly clearing jams on this machine.