Violation Detail
Standard Cited: 19260451 G03 I General requirements.
Inspection Nr: 1764905.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,323.00
Current Penalty: $5,323.00
Issuance Date: 10/17/2024
Nr Instances: 2
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 11/13/2024
Related Event Code (REC): I
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 10/17/2024 | $5,323.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(g)(3)(i): When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights. a)At or near 474 Hudson Terrace, Englewood Cliffs - Exterior Frame Scaffold - Stairtower: employee engaged in masonry work was exposed to fall hazards of approximately 42 feet while anchoring his lanyard to a scaffold leg crossbrace anchor pin, on or about 7/29/24. b)At or near 474 Hudson Terrace, Englewood Cliffs - Exterior Frame Scaffold - Stairtower: employee engaged in masonry work was exposed to fall hazards of approximately 42 feet while anchoring his lanyard to a scaffold crossbrace, on or about 7/29/24.
Translate