Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1759026.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 11/12/2024
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 11/26/2024
Gravity: 10
Report ID: 0523300
Contest Date: 12/05/2024
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 12/09/2024 | $16,131.00 | 11/26/2024 | Serious | |
Penalty | Z: Issued | 11/12/2024 | $16,131.00 | 11/26/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about and times prior to June 28, 2024, hazardous energy control procedures were not utilized for the Hytrol Model TH Conveyor System to protect employees from the unexpected startup during maintenance and servicing activities such as unjamming. b) On or about and throughout June 1, 2024, to June 27, 2024, hazardous energy control procedures were not utilized for the Hytrol Model TH Conveyor to protect employees from unexpected startup during maintenance and servicing activities such as unjamming.