Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1746271.015
Citation: 01001
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $14,518.00
Current Penalty: $10,000.00
Issuance Date: 07/25/2024
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 08/15/2024
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/15/2024 | $10,000.00 | Other | ||
| Penalty | Z: Issued | 07/25/2024 | $14,518.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about May 01, 2024, the employer did not ensure that one or more methods of machine guarding was provided to protect the operator from the moving mechanical parts of the upper ejection system while operating the CB-18 -094 core machine.
Translate