Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1740086.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $63,382.00
Current Penalty: $11,524.00
Issuance Date: 05/07/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/27/2024
Gravity: 5
Report ID: 0111400
Contest Date:
Final Order: 05/28/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/28/2024 | $11,524.00 | 06/27/2024 | Serious | |
Penalty | Z: Issued | 05/07/2024 | $63,382.00 | 06/27/2024 | Repeat |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Location: 761 Joseph E. Warner Blvd. Taunton, MA 02780 On or about 04/09/2024, employees were exposed to amputation hazards where energy control procedures were not utilized while employees were cleaning the gear pump in the compound mixing department. Prysmian Group Specialty Cables LLC was previously cited for a violation of this occupational safety and health standard, which was contained in OSHA inspection number 1601208, citation number 1, item number 1 and was affirmed as a final order on (07/26/2022), with respect to a workplace located at 1 Tamaqua Blvd, Schuylkill Haven, PA 17972.