Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1734202.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 08/26/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 09/30/2024
Gravity: 10
Report ID: 0213100
Contest Date: 09/20/2024
Final Order: 02/12/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/12/2025 | $16,131.00 | 09/30/2024 | Other | |
Penalty | C: Contested | 09/20/2024 | $16,131.00 | 09/30/2024 | Serious | |
Penalty | Z: Issued | 08/26/2024 | $16,131.00 | 09/30/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a) Worksite, SAW-Cobleskill Value Added: On or about March 1, 2024, the employer did not establish a written program consisting of the control of hazardous energy, associated equipment specific lockout/tagout procedures, authorized training, and periodic inspections for employees performing maintenance on a Conception CRP 2000 Finger Jointing System, Press Section, Model Number 4613, Serial Number J120E.