Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1718019.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.00
Issuance Date: 04/02/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/10/2024
Gravity: 10
Report ID: 0523300
Contest Date:
Final Order: 04/29/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/29/2024 | $12,098.00 | 05/10/2024 | Serious | |
Penalty | Z: Issued | 04/02/2024 | $16,131.00 | 04/16/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 13, 2023, hazardous energy control procedures for the Yaskawa ArcWorld Robotic Welder were not utilized to protect employees from the unexpected start-up during maintenance and servicing activities.