Violation Detail
Standard Cited: 19260451 B03 General requirements.
Inspection Nr: 1715316.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,452.00
Current Penalty: $5,000.00
Issuance Date: 05/28/2024
Nr Instances: 9
Nr Exposed: 2
Abatement Date: 06/20/2024
Gravity: 10
Report ID: 0627500
Contest Date:
Final Order: 06/04/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/04/2024 | $5,000.00 | 06/20/2024 | Serious | |
Penalty | Z: Issued | 05/28/2024 | $6,452.00 | 06/14/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.451(b)(3): The front edge of all platforms was not 14 inches (36 cm) or less from the face of the work, and no guardrail systems were erected along the front edge and/or no personal fall arrest systems were used in accordance with paragraph (g) of this section to protect employees from falling. On or about December 7, 2024, on the north side of the jobsite; employees utilized scaffold platforms more than 14 inches (36 cm) from the face of the work while dissasembling the scaffold on the exterior of the building.