Violation Detail
Standard Cited: 19100030 C01 Training requirements.
Inspection Nr: 1715127.015
Citation: 01001
Citation Type: Serious
Abatement Status:
Initial Penalty: $8,067.00
Current Penalty: $2,067.00
Issuance Date: 05/29/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 07/03/2024
Gravity: 5
Report ID: 0830300
Contest Date: 06/25/2024
Final Order: 09/23/2025
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/23/2025 | $2,067.00 | 07/03/2024 | Serious | |
Penalty | C: Contested | 06/25/2024 | $8,067.00 | 07/03/2024 | Serious | |
Penalty | Z: Issued | 05/29/2024 | $8,067.00 | 07/03/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
1910.30(c)(1) When changes in the workplace render previous training obsolete or inadequate; (a) In December 2023, and times prior, at 503 Broadway Ave., Finely, ND, the employer did not ensure employees were adequately trained on the use of fall protection equipment when the weather conditions became inclement, requiring work to be performed under the fall protection system.