Violation Detail
Standard Cited: 19100147 A02 III A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1713867.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $9,678.60
Issuance Date: 05/15/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/04/2024
Gravity: 10
Report ID: 0317900
Contest Date:
Final Order: 06/30/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/30/2024 | $9,678.60 | 06/04/2024 | Other | |
Penalty | Z: Issued | 05/15/2024 | $16,131.00 | 06/04/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(a)(2)(iii)(A) - Work on cord and plug connected electric equipment for which exposure to the hazards of unexpected energization or start up of the equipment was not controlled by the unplugging of the equipment from the energy source and by the plug being under the exclusive control of the employee performing the servicing or maintenance: a) 2139 28th Street Southwest, Allentown, PA: Folder Machine - On or about November 22, 2023, employee(s) performing maintenance activities were exposed to unexpected machine startup due to the cord and plug of the machine not being maintained under exclusive control of the employee.