Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1699007.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $57,620.00
Current Penalty: $9,000.00
Issuance Date: 03/07/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 04/02/2024
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 03/25/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/25/2024 | $9,000.00 | 04/02/2024 | Serious | |
Penalty | Z: Issued | 03/07/2024 | $57,620.00 | 04/02/2024 | Repeat |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3):All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s) On or about September 16, 2023, at the Fresh Beef Finishing Line #2 Grinder, energy isolation devices were not operated and utilized prior to opening a hatch on the unload auger, exposing employees to hazards from rotating parts.