Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1696003.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,162.00
Current Penalty: $5,500.00
Issuance Date: 10/13/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/07/2023
Gravity: 5
Report ID: 0524700
Contest Date:
Final Order: 11/02/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/02/2023 | $5,500.00 | 11/07/2023 | Serious | |
| Penalty | Z: Issued | 10/13/2023 | $11,162.00 | 11/07/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): a. Haas Door Company, at a worksite located at 320 Sycamore Street, Wauseon, Ohio 43567: On or about August 30, 2023, the employer did not ensure energy control applications steps, isolating electrical and mechanical energy on the #3 Style Line were implemented prior to an employee entering the line's perimeter guarding. Employees performing service and maintenance tasks, such as adjustments to the "flipper arm" while the line was in an energized condition, were exposed to caught in hazards.