Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1694627.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $10,000.00
Issuance Date: 11/29/2023
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 12/26/2023
Gravity: 5
Report ID: 0316700
Contest Date:
Final Order: 12/28/2023
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/28/2023 | $10,000.00 | 12/26/2023 | Serious | |
Penalty | Z: Issued | 11/29/2023 | $13,260.00 | 12/26/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Soup Packing Line - The employer did not conduct an annual periodic inspection of the lockout/tagout procedure for the metal detector conveyor (with the Lock Inspection Systems MET 30+ head, serial number 40842/2), in accordance with the standard, exposing employees to machinery hazards, on or about August 30, 2023. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.