Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1686481.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $16,131.00
Issuance Date: 01/26/2024
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/01/2024
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 02/21/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/21/2024 | $16,131.00 | 04/01/2024 | Serious | |
Penalty | Z: Issued | 01/26/2024 | $16,131.00 | 02/22/2024 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: On or about July 27, 2023, at the Tire Room- Area B- Channels 1- 8, employees perform repairs and maintenance activities requiring energy control and procedures for the DRB tire machines did not have outlined steps of shutting down, isolating, and blocking machine parts, exposing employees to struck-by hazards.