Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1679484.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,523.00
Current Penalty: $8,766.10
Issuance Date: 10/23/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 11/17/2023
Gravity: 5
Report ID: 0418300
Contest Date:
Final Order: 11/20/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 11/20/2023 | $8,766.10 | 11/17/2023 | Serious | |
| Penalty | Z: Issued | 10/23/2023 | $12,523.00 | 11/17/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) On or about 06/20/2023 - Roll Coater Area, PERSICO Coater machine, Serial #30109L, employees were exposed to caught-in hazards when procedures for cleaning the rollers of the machine were not developed.