Violation Detail
Standard Cited: 19100219 M02 I Mechanical power-transmission apparatus.
Inspection Nr: 1676159.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $12,000.00
Issuance Date: 10/03/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/13/2023
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 10/27/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/27/2023 | $12,000.00 | 10/13/2023 | Serious | |
| Penalty | Z: Issued | 10/03/2023 | $15,625.00 | 10/13/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(m)(2)(i): Expanded metal, sheet or perforated metal, and wire mesh was not securely fastened to frame. On or about June 2, 2023, an employee was exposed to amputation hazards from the Overpressor Screw #370/Drainer Screw in the Cooker Room, while shoveling material from the mezzanine/floor back into the screw and while climbing over the screw via the guarded section to access the mezzanine/floor area on the other side of the screw because the guard could become dislodged by product and was not securely fastened to the frame.