Violation Detail
Standard Cited: 19100147 C07 I B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1666286.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,063.00
Current Penalty: $8,437.80
Issuance Date: 07/14/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/09/2023
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 07/28/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/28/2023 | $8,437.80 | 08/09/2023 | Serious | |
Penalty | Z: Issued | 07/14/2023 | $14,063.00 | 08/09/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: In the CNC Area, employee(s) engaged in automated CNC machine activities were not instructed in the purpose and use of the energy control procedure or provided any training on the topic of lockout / tagout before using the automated CNC machine. The automated CNC machine is as follows: 1. Make: Emmegi; Model: Phantomatic TS Star; Designation: Centrto Di Lavoro; Serial #: C124615.