Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1666276.015
Citation: 01001
Citation Type: Other
Abatement Date: 10/18/2023 2
Initial Penalty: $6,641.00
Current Penalty: $0.00
Issuance Date: 09/21/2023
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0523400
Contest Date:
Final Order: 10/18/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/18/2023 | $0.00 | 10/18/2023 | Other | |
Penalty | Z: Issued | 09/21/2023 | $6,641.00 | 10/18/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) On or about April 27, 2023, and dates prior, the zinger drive pulley assembly at converting machine #8 was not adequately guarded. This allowed the employee(s) to access the powered pulley and belt, exposing the employee(s) to ingoing nip point and amputation hazard.