Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1652586.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,278.00
Current Penalty: $12,278.00
Issuance Date: 06/01/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 06/15/2023
Gravity: 5
Report ID: 0523300
Contest Date:
Final Order: 06/15/2023
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/15/2023 | $12,278.00 | 06/15/2023 | Other | |
| Penalty | Z: Issued | 06/01/2023 | $12,278.00 | 06/15/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i):Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 15, 2023, the employer did not ensure the procedure for controlling hazardous energy on the Line 8 Tiromat machine (Rebuilt S/N 500/494) was developed prior to an employee reaching into the machine to clear a jam and/or perform adjustments, exposing employee(s) to amputation hazard(s).