Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1652041.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,625.00
Current Penalty: $12,500.00
Issuance Date: 03/31/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 04/19/2023
Gravity: 10
Report ID: 0316400
Contest Date:
Final Order: 05/11/2023
Related Event Code (REC): A
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/11/2023 | $12,500.00 | 04/19/2023 | Serious | |
| Penalty | Z: Issued | 03/31/2023 | $15,625.00 | 04/19/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Centrifuge Area: On February 17, 2023 and times prior, employees operated a hydraulic press to remove waves from metal centrifuge parts. The employees hands were within in two to six inches of the hydraulic press ram that was not equipped with a point of operation guard to prevent access to the danger zone during operation, exposing employees to crushing and amputation hazards.