Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1635674.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $8,287.00
Current Penalty: $8,287.00
Issuance Date: 01/09/2023
Nr Instances: 2
Nr Exposed: 200
Abatement Date: 05/22/2023
Gravity: 5
Report ID: 0111700
Contest Date:
Final Order: 02/21/2023
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/21/2023 | $8,287.00 | 05/22/2023 | Other | |
| Penalty | Z: Issued | 01/09/2023 | $8,287.00 | 05/22/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Location: 1st floor conveyor motor adjacent to PDI-2 / PDI-1 On or about November 22, 2018, employees were not protected from scalping & amputation hazards from the exposed, rotating shaft connecting the Toshiba motor to the conveyor system. A guard was not installed to prevent employee contact with the rotating shaft. b) Location: 1st floor conveyor motor adjacent to PD3-1 / PD3-2 On or about November 22, 2018, employees were not protected from scalping & amputation hazards from the exposed, rotating shaft connecting the Toshiba motor to the conveyor system. A guard was not installed to prevent employee contact with the rotating shaft.