Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1620720.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $10,000.00
Issuance Date: 01/04/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/17/2023
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 01/30/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/30/2023 | $10,000.00 | 01/17/2023 | Serious | |
| Penalty | Z: Issued | 01/04/2023 | $14,502.00 | 01/17/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Packaging Department - On or about September 2, 2022, authorized employees were required to perform servicing and/or maintenance on the Multivac Vaccum Packaging Machine #1 Model #R140 and other operating equipment. The employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.