Violation Detail
Standard Cited: 19260502 D15 I Fall protection systems criteria and practices.
Inspection Nr: 1616153.015
Citation: 01001
Citation Type: Serious
Abatement Date: 02/22/2023 2
Initial Penalty: $15,625.00
Current Penalty: $15,000.00
Issuance Date: 02/02/2023
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC): R
Gravity: 10
Report ID: 0111700
Contest Date: 03/21/2023
Final Order: 09/18/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/18/2023 | $15,000.00 | 02/22/2023 | Serious | |
Penalty | C: Contested | 04/04/2023 | $15,625.00 | 02/22/2023 | Serious | |
Penalty | Z: Issued | 02/02/2023 | $15,625.00 | 02/22/2023 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.502(d)(15)(I): Anchorages used for attachment of personal fall arrest equipment were not designed, installed, and used as part of a complete personal fall arrest system which maintains a safety factor of at least two: a) Main House- On or about August 14, 2022, an employee sustained injuries during a fall from a roof where the anchor point for their fall protection system failed. The SeamSAFE M6 standing seam metal roof anchor that the employer attached to the roof as part of a personal fall arrest system did not support at least twice the intended load. b) Main House- On or about August 14, 2022, an employee working from the roof was not protected from a fall hazard where their personal fall arrest system was not complete; their personal fall arrest system did not include a deceleration device, as required by the SeamSafe M6 standing seam metal roof anchor and the SAFEWAZE SW-EX8000 removable trailing rope grab to which they were connected. The SeamSafe M6 standing seam metal roof anchor failed when it was impacted due to the employee falling from the roof without the use of a deceleration device. c) Barn/Garage roof- On or about August 14, 2022, employees working from the roof were not protected from a fall hazard where a Guardian 2-way standing roof anchor was installed on a roof with a roof pitch greater than 4/12. The Guardian 2-way standing seam roof anchor was not rated for use on a roof with a pitch greater than 4/12.