Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1606320.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $5,283.00
Current Penalty: $2,000.00
Issuance Date: 07/29/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 02/13/2023
Gravity: 1
Report ID: 0418100
Contest Date: 08/22/2022
Final Order: 02/13/2023
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/13/2023 | $2,000.00 | 02/13/2023 | Other | |
| Penalty | C: Contested | 08/26/2022 | $5,283.00 | 09/15/2022 | Serious | |
| Penalty | Z: Issued | 07/29/2022 | $5,283.00 | 09/15/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by ingoing nip point, rotating parts and/or flying chips or sparks: a. On or about July 07, 2022, 5055 South Royal Atlanta Drive, Tucker, GA (Line #I Conveyor Switching Station) - Employees were exposed to caught in-between hazard. The side panel of the plexi-glass which serves as the machine guarding to the moving parts of the conveyor pinch point area (slide plate and transfer roller) had an opening where the plexi-glass panel met the side of the conveyor.
Translate