Violation Detail
Standard Cited: 19100134 M02 I B Respiratory Protection.
Inspection Nr: 1601988.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 11/30/2022
Nr Instances: 1
Nr Exposed: 12
Abatement Date: 12/27/2022
Gravity:
Report ID: 0418300
Contest Date:
Final Order: 12/28/2022
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 11/30/2022 | $0.00 | 12/27/2022 | Other |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.134(m)(2)(i)(B): The employer did not establish a record of the qualitative and quantitative fit tests administered to an employee which included the type of fit test performed: a) On or about June 14, 2022, the employer did not establish fit test records that included the type of fit test performed. The employer required employees to wear half-facepiece respirators when working on the Wilputte battery bench.