Violation Detail
Standard Cited: 19260404 B01 II Wiring design and protection.
Inspection Nr: 1595834.015
Citation: 01001
Citation Type: Serious
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $2,735.00
Current Penalty: $2,735.00
Issuance Date: 11/08/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 11/17/2022
Gravity: 5
Report ID: 0316100
Contest Date:
Final Order: 12/08/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/08/2022 | $2,735.00 | 11/17/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) On or about May 11, 2022; Roof area, top floor; Employees were operating double-insulated electrical equipment such as, but not limited to, portable circular saws without ground-fault interrupters in place to protect from electrical shock. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.