Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1594361.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $8,000.00
Issuance Date: 09/30/2022
Nr Instances: 2
Nr Exposed: 25
Abatement Date: 01/31/2023
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/27/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/27/2022 | $8,000.00 | 01/31/2023 | Serious | |
Penalty | Z: Issued | 09/30/2022 | $14,502.00 | 10/27/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. (a) On or about May 5, 2022, the employer did not ensure that machine specific procedures for the control of hazardous energies (LO/TO) were utilized during service and maintenance of the 116CL Browne and Sharp swiss screw machine. Employees were performing setup operations without the use of LO/TO. Hazardous energies present on the equipment include, but are not limited to, pneumatic, hydraulic, electrical, and mechanical. b) On or about May 5, 2022, the employer did not ensure that machine specific procedures for the control of hazardous energies (LO/TO) were utilized during service and maintenance of the G9 Centerless grinder robotic cell area. Employees were performing adjustment operations by entering the area of the robotic arm without the use of LO/TO. Hazardous energies present on the equipment include, but are not limited to, pneumatic, hydraulic, electrical, and mechanical.