Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1591485.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $8,000.00
Issuance Date: 07/18/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/22/2022
Gravity: 10
Report ID: 0134000
Contest Date:
Final Order: 08/24/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/24/2022 | $8,000.00 | 08/22/2022 | Serious | |
Penalty | Z: Issued | 07/18/2022 | $14,502.00 | 08/22/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: Location - 50 Foundation Avenue, Haverhill, MA 01835. On or about 4/22/2022, periodic inspections of the energy control procedures developed under the energy control program for the Ampco ZP3 Series Homogenizer #2 Stuffing Pump were not conducted.