Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1580940.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,801.00
Current Penalty: $2,825.00
Issuance Date: 06/09/2022
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 06/29/2022
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 06/29/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/29/2022 | $2,825.00 | 06/29/2022 | Serious | |
Penalty | Z: Issued | 06/09/2022 | $5,801.00 | 06/29/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3):All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) Production floor, slitter machine - On or about February 15, 2022, an employee adjusted the slitter blades without ensuring the machine was fully isolated from all energy sources.