Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1579893.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 04/13/2022
Nr Instances: 1
Nr Exposed: 24
Abatement Date: 05/09/2022
Gravity: 10
Report ID: 0729700
Contest Date:
Final Order: 05/10/2022
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 04/13/2022 | $14,502.00 | 05/09/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: On or about February 15th, 2021, employees were exposed to burn and caught-in-between hazards at Rotovac 7. In that, the buttons that operate the machine were not properly covered to prevent an employee from activating the machine while their hands were inside.