Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1578880.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,687.00
Current Penalty: $5,812.20
Issuance Date: 07/21/2022
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 08/19/2022
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 08/18/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/18/2022 | $5,812.20 | 08/19/2022 | Serious | |
| Penalty | Z: Issued | 07/21/2022 | $9,687.00 | 08/19/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven (7) feet or less from floor or working platform was not enclosed with stationary casing(s) in accordance with paragraphs (m) and (o) of this section: On or about February 16, 2022, employees working in the Slurry room were exposed to entanglement hazards because: a. the vertical drive shaft used to turn the Mixer for Dissolver #3 was not guarded or enclosed in accordance with the standard. b. the vertical drive shaft used to turn the Mixer for Dissolver #7 was not guarded or enclosed in accordance with the standard.