Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1572362.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $14,502.00
Current Penalty: $10,151.40
Issuance Date: 02/16/2022
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 03/17/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/17/2022 | $10,151.40 | Serious | ||
| Penalty | Z: Issued | 02/16/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(4)(ii)(B):Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy; On or about 1/12/2022, Hitachi Energy USA Inc. had not identified, developed and utilized specific procedural steps for shutting down, isolating, blocking and securing hazardous energy for several machines in the plant to include, but not limited to the following: a) Reel-O-Matic Wire Rope Cutter, Model CTL/CVS/2000 - SN 1-149-R0; b) Cincinnati Series 9 Brake Press; c) And, an Accurpress 30 Ton Brake Press