Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).

Inspection Nr: 1568435.015

Citation: 01001

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $3,108.00

Current Penalty: $2,000.00

Issuance Date: 02/16/2022

Nr Instances: 1

Nr Exposed: 2

Abatement Date: 03/25/2022

Gravity: 5

Report ID: 0521400

Contest Date:

Final Order: 03/15/2022

Related Event Code (REC): R

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 03/15/2022 $2,000.00 03/25/2022 Serious  
Penalty Z: Issued 02/16/2022 $3,108.00 03/25/2022 Serious  

Text For Citation: 01 Item/Group: 001 Hazard:

29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energization, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: Production Area, Castaly Double-Sided Planer (Model No. PL 18S, Serial No. YN201005) and Morgan Band Re-Saw (Serial No. 0607021605). On or about November 19 through December 14, 2021, employees were exposed to amputation hazards when performing servicing and maintenance activities such as cleaning of wood dust and changing of saw blades. Employees did not de-energize and lockout the machines prior to performing servicing and maintenance. The employer did not implement and maintain a lockout/tagout program consisting of specific energy control procedures, employee training and periodic inspections as follows: a) Procedures for the control of hazardous energy were not developed, documented and utilized by the employer. b) Training of "Authorized", "Affected" and "Other" employees was not conducted and certified by the employer. Employees authorized to perform lockout/tagout were not informed of and trained to control hazardous energy sources according to specific procedures. Lockout devices were not provided. c) Periodic inspections of the energy control procedures were not conducted and certified by the employer at least annually to ensure that the procedures and requirements of the standard were being followed. Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.