Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1567319.015
Citation: 01001
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $10,151.00
Current Penalty: $5,000.00
Issuance Date: 05/20/2022
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 06/16/2022
Gravity: 10
Report ID: 0418300
Contest Date: 06/03/2022
Final Order: 11/10/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/10/2022 | $5,000.00 | 06/16/2022 | Other | |
Penalty | C: Contested | 06/07/2022 | $10,151.00 | 06/16/2022 | Serious | |
Penalty | Z: Issued | 05/20/2022 | $10,151.00 | 06/16/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining shall be conducted whenever the employer has reason to believe that there are deviations from an employee's knowledge of energy control procedures. (a) On or about 11/24/2021, at 900 Goodwill Road, Guntersville, Alabama, in the hatchery, the energy control training procedures were not followed.