Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1564317.015
Citation: 01001
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,653.00
Current Penalty: $13,653.00
Issuance Date: 01/11/2022
Nr Instances: 1
Nr Exposed: 25
Abatement Date: 01/21/2022
Gravity: 10
Report ID: 0524700
Contest Date:
Final Order: 02/22/2022
Related Event Code (REC): A;R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | Z: Issued | 01/11/2022 | $13,653.00 | 01/21/2022 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. National Electrical Carbon Products, Inc. - Fostoria, Ohio: On or about November 6, 2022, the employer failed to ensure that the S-Winder associated with the slot furnace located in building 72 was guarded to protect employees from rotating part hazards. Employees that fed the winder with material were exposed to being caught by the ends of the roll's rotating shafts, and also the ingoing nip point created between the rolls; an employee sustained injuries to the arm after being caught in the nip point.