Violation Detail
Standard Cited: 19261053 B01 Ladders.
Inspection Nr: 1563536.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $3,315.00
Current Penalty: $3,315.00
Issuance Date: 04/21/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 06/03/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 04/21/2022 | $3,315.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Woodsboro Apartments, Building 8576-8586, Baldwinsville, NY 13027, on or about 11/10/21: Workers were accessing a 6:12 pitch roof with an extension ladder that was placed against the rake of the roof, allowing for 2 feet 9 inches above the upper landing on the downslope side of the ladder, and 1 foot 6 inches on the upslope side of the ladder.