Violation Detail
Standard Cited: 19100212 B General requirements for all machines.
Inspection Nr: 1558590.015
Citation: 01001
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $14,502.00
Current Penalty: $10,876.50
Issuance Date: 04/05/2022
Nr Instances: 4
Nr Exposed: 10
Abatement Date:
Gravity: 10
Report ID: 0627100
Contest Date:
Final Order: 05/02/2022
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/02/2022 | $10,876.50 | Serious | ||
Penalty | Z: Issued | 04/05/2022 | $14,502.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: In the workshop, the following blower machines designed to be bolted to the floor were not anchored: a) Blower Machine #1, Wise Feeder, Serial Numbers: NC6597/WK4X36, Drum Model VWOX36, Feeder Model NC6596, manufactured 2003. b) Blower Machine #2, Wise Feeder, Serial Number: NC4013, Drawing Number: D10945, manufactured 1992. c) Blower Machine # 3, Lumus Feeder, Wise Control Panel, Serial Number: 3692, Drawing Number: D10828, manufactured 1991; Carolina Blower Corp Nozzle Blower, Serial Number: B9445, Model Number: 30656D; Wise Feeder Bed, Serial Number: 3675, Model Number: EX-36X6. d) Blower Machine #4, Wise Feeder, Serial Number: 1564/01, Panel Model Number: NC6339, manufactured 2001.